Skip to content

GSM STARTER

  • All in One (Starter, Mobile Operation, Protection, Timer)
  • In build Control Switching Device Algorithm
  • 4 Digit Seven Segment display
  • Manual and Remote (Using GSM network) operations
  • Timer facility
  • Power restore auto start (Timer Enabled)
  • Voltage, Current and power factor measurement on display
  • Adjustable low voltage and High voltage settings
  • 3 Tactile switches for settings
  • On/Off Switches for panel operation
  • Load Capacity : 2HP – 7.5HP
  • Different Operating Voltage 415VAC
  • Internal CT capacity : 20amp
  • Easy to Install
  • Motor Stator Problem
  • Cable Faults
    • Motor Side single phasing
    • Line to Line Faults
    • Triple line Faults
    • Line to Earth Faults
    • Triple Line to Earth Faults
    • Winding unbalance
  • Dry Run / Under load
  • Overload
  • Under Voltage
  • Over Voltage
  • Phase Fail
  • Phase Sequence Change
  • Voltage Unbalance

CYCLIC TIMER WITH STARTER

  • All in One (Starter, Cyclic Timer, Protection)
  • In build Control Switching Device Algorithm
  • 4 Digit Seven Segment display
  • Manual and auto as per settings provided by user
  • Cyclic Timer Lowest setting 1 minute
  • Power restore auto start (Timer Enabled)
  • Voltage, Current and power factor measurement on display
  • Adjustable low voltage and High voltage settings
  • 3 Tactile switches for settings
  • On/Off Switches for panel operation
  • Load Capacity : 2HP – 7.5HP
  • Different Operating Voltage 415VAC
  • Internal CT capacity : 20amp
  • Easy to Install
  • Motor Stator Problem
  • Cable Faults
    • Motor Side single phasing
    • Line to Line Faults
    • Triple line Faults
    • Line to Earth Faults
    • Triple Line to Earth Faults
    • Winding unbalance
  • Dry Run / Under load
  • Overload
  • Under Voltage
  • Over Voltage
  • Phase Fail
  • Phase Sequence Change
  • Voltage Unbalance

AGRIAUTO

  • In build Control Switching Device Algorithm
  • 4 Digit Seven Segment display
  • Manual and Remote (Using GSM network) operations
  • Timer facility
  • Power restore auto start
  • Voltage, Current and power factor measurement on display
  • Adjustable low voltage and High voltage settings
  • 3 Tactile switches for settings
  • On/Off Switches for panel operation
  • Load Capacity : 12.5HP
  • Different Operating Voltage 24VDC/110VAC/230VAC/415VAC
  • Internal CT capacity : 25amp
  • Easy to Install

SINGLE PHASE STARTER

  • Starting and Runing capacitor
  • 4 Digit Seven Segment display
  • Manual operations
  • Current Settings as per motor capacity
  • Single Phase operation
  • Voltage, Current measurement on display
  • Adjustable low voltage and High voltage settings
  • Load Capacity : 1HP,1.5HP, 2HP, 3HP and 5HP
  • Operating Voltage 230VAC
  • Internal CT capacity : 60amp External CT
  • Easy to Install